The Villavent central extract system is
developed for continuous use and with a minimum of maintenance and
service.
|
1. |
Cleaning
the extract filter
- as necessary, normally every four months.
(a) The aluminium grease
filter on the extract side inside the unit must be cleaned
regularly. Wash in hot soapy water or in the dish washer.
(b) Do not use detergent containing ammonia.
(c) Replace the filter when necessary. Click
here to view heat recovery spare parts.
|
|
2. |
Bag
Filter
The bag filter cannot be cleaned and must be changed as necessary.
Click
here to view heat recovery spare parts.
|
|
3. |
Checking
the heat exchanger block - once a year
Even if the required maintenance in items 1 and 2 above
is carried out, dust may build up in the exchanger block. It is
therefore of vital importance for the upkeep of high efficiency
that the exchanger block is removed from the unit and cleaned
periodically. Wash in hot soapy water.
Do not
use detergent containing ammonia.
|
|
4. |
Checking
the fans - once a year
Even if the required maintenance, such as cleaning/changing of
filters is carried out, dust and grease may slowly build up inside
the fans. This will reduce efficiency. The fans should be gently
scraped using a non metallic scraper eg body of a bic biro.
|
|
5. |
Checking
condensate drain - once a year
Condensate drain (drain pipe) may after some time get
blocked by particles from the extract air. Check that the drain
pipe is open by pouring some water into the condensate tray in the
bottom of the unit. Clean the water lock and drain pipe as
necessary.
|
|
6. |
Cleaning
extract louvers and inlet diffusers - as necessary
The system supplies fresh air to your home and extracts
the used indoor air via the duct system and diffusers/louvers.
Diffusers and louvers are mounted in ceilings/walls in bedrooms,
living room, wet rooms, WC etc. Remove diffusers and louvers and
wash in hot soapy water as required.
Diffusers/louvers must
not be exchanged.
|
|
7. |
Checking
the fresh air intake
Leaves and pollution could plug
up the air intake grille and reduce the capacity. Check the air
intake grille at least twice year, and clean as necessary.
|
Troubleshooting /
Service [back
to top]
Should problems occur please refer to
the items below before calling our service
representative.
|
1. |
Fan(s)
Do Not Start
Check that all fuses and plugs are connected (mains supply and fan
plugs).
|
|
2. |
Reduced
Airflow
(a) Check the setting of airflow on control panel.
(b) Ensure the motors are running.
(c) Change/clean of filter if required.
(d) Clean diffusers/louvers if required.
(e) Cleaning of fans/exchanger block required.
(f) Is roof unit/air intake blocked?
(g) Duct system - check visible duct runs for damage and/or build
up of dust/pollution.
(h) Check diffuser/louver openings for blockages/dust build up.
|
|
3. |
Cold
Supply Air
(a) Check the supply air temperature on the control panel.
(b) Clean the extract filter if required.
(c) Ice in exchanger block. Turn off the unit and let the ice
melt. Call your service engineer if this is repeated.
(d) Check if summerblock is installed in the unit - if so remove
and replace with heat exchanger block.
|
|
4. |
Noise
/ Vibrations
(a) Carry out all checks as for reduced airflow (in particular
extract fans).
(b) Clean the fan impellers.
(c) Remove the fans and check that the screws holding the fans are
tightened.
(d) Check if the unit is free standing and that anti-vibration
pads are installed under the unit.
|
|
5. |
Water
Leakage
(a) Check that the condensate pipe is installed with a gradient
toward the drainage point.
(b) Check that free standing units are installed with a gradient
toward the condensate drain
(c) If installed in a space likely to experience temperatures
below freezing ensure condensate pipe is insulated.
|
|
6. |
Service
Before calling our service representative
make a note
of the specification and production number, this can be seen on
data the data plate which is situated on the unit. |